banner

Diamond Saw Blade Debugging Operation And Process

Jul 11, 2021

Carbide saw blade for aluminum alloy blanking, sawing, slot milling and grooving. The following editor will introduce to you the precautions when using the diamond saw blade device.


1. When installing, check whether the saw blade has cracks, twists, and tooth loss.

2. After the saw blade is installed, it is necessary to confirm whether the center hole of the saw blade is firmly fixed on the flange of the saw table, and then gently push the saw blade by hand to confirm whether the saw blade rotates eccentrically.

3. It is necessary to align the cutting direction indicated by the arrow of the saw blade with the rotation direction of the saw table. It is strictly forbidden to place the device in the direction. The reverse installation will cause the saw blade to drop teeth.

4. Before use, let the saw blade pre-rotate for one minute before cutting.

5. Stop inversion, inversion will lead to tooth loss, and there will be serious risks.

6. The saw blade should be wiped clean before installation. If there is resin on the saw blade, it needs to be wiped off with thinner.

7. Every installation must keep the flange and gasket clean and flat.

8. Do not exceed the specified speed during use. (The speed is about 4200, the domestic machine is about 2500)

9. When installing, first recognize the function and use of the saw table to avoid accidents.


If the saw blade is not adjusted correctly, the quality of the sawing workpiece will be unstable, and even cracked or chipped teeth will occur, including affecting the function and service life of the equipment. Therefore, the correct debugging of the saw blade is very important for cutting equipment.


Saw blade debugging operation and process:

1. First of all, the flange part of the equipment should be clean and clean, maintain a good working environment, carefully check the direction of the saw blade, do not reverse the installation, you can watch the trademark on the circular saw blade, and the side with the trademark is facing up. , and tighten with the specified screws.

2. Wipe and clean the equipment and required items, and place them in the designated position. When debugging, ensure that they are locked with specific screws. After that, you should check whether there is any looseness. You need to pay attention to the fixation of the protective cover position to ensure safety and no accident; Clean the orientation of the guide rail. After the operation is completed, gently try to turn it down by hand to see if it is correct, so as to ensure the rotation and circulation, and there is no jamming phenomenon.

3. Special attention is that the wire brush of the saw blade must be debugged, otherwise there will be unforeseen problems! The sawtooth bag shall prevail.

4. When the equipment is in operation, the circular saw blade is rotating, and there will be a reversal process after the power supply is cut off. After the saw blade stops, you can touch it for replacement and debugging. It is necessary to ensure that the equipment is stopped and the saw blade stops. After opening the saw blade cover, when replacing the saw blade, it is necessary to cut off the power supply first.


About the settings of the saw blade:

It is necessary to check the forward end of the equipment, the proximity switch and the saw blade cover on the lateral clamping seat to ensure that the metal materials that have been set can correspond to each other. It is not necessary to adjust the position of the backward end, and the rear end cannot be adjusted. The orientation of the end is also fixed and cannot be adjusted. (Note that this scale cannot be used for square or special-shaped steel, so the scale saw blade may be damaged.) If metal cutting equipment is required to saw irregular materials, move towards the horizontally clamped switch position, and screw the screw slightly Relax and adjust the fixing frame according to the actual situation. If the equipment is in operation, the LS sensor block cannot be adjusted at this time. It is necessary to wait for the equipment to stop before debugging (please cut off the power supply together), otherwise it is very easy to cause an accident. The oil mist in the equipment is about one drop in 10 seconds on average. If it accidentally enters the body, it is necessary to induce vomiting immediately. If the amount is too much, you should seek medical attention immediately; during use, it is found that oil mist enters the eyes. , please rinse with plenty of water immediately. In winter or when the temperature is low, take precautions to avoid freezing.


Product Recommended